We've been committed to offering easy,time-saving and money-saving one-stop purchasing support of consumer for Nitrogen System Cost, Nitrogen Filter Membrane, Liquid Oxygen Tank, We welcome customers, business associations and friends from all parts of the world to contact us and seek cooperation for mutual benefits.
OEM Hydrogen Compressor Model Manufacturers – High Stable Belt Driven Ammonia unloading compressor – Huayan Detail:

AMMONIA UNLOADING COMPRESSOR

Ammonia unloading compressor
product description
This series of oil-free lubrication compressors is one of the products produced by our company. The product has the characteristics of low rotation speed, high component strength, stable operation, long service life, and convenient maintenance. Among them, the ZW series compressor is in the form of a unit. It integrates compressor, gas-liquid separator, filter, two-position four-way valve, safety valve, check valve, explosion-proof motor, and chassis. It has the characteristics of small size, lightweight, low noise, good airtightness, easy installation, and simple operation.
This product is mainly used for unloading, loading, refilling, gas recovery, and residual liquid recovery of LPG/C4, propylene, and liquid ammonia. It is widely used in gas, chemical, energy, and other industries, and is the key equipment for gas, chemical, energy, and other industries.

Note: In the process of unloading, the compressor pressurizes the gas from the storage tank and then presses it into the tank truck through the gas phase pipeline, and presses the liquid from the tank truck to the storage tank through the pressure difference of the gas phase to complete the unloading process. When the gas phase is pressurized, the temperature of the gas phase will increase. At this time, it is not necessary to perform forced cooling, because if the gas phase is compressed and then cooled, it is easy to liquefy and it is difficult to establish a pressure difference in the gas phase, which is not conducive to the replacement of the gas phase and the liquid phase. In short, it will cause an extension of the unloading process time. If residual gas recovery is required, a cooler can be used to forcibly cool the gas phase during the residual gas recovery operation in order to recover the residual gas as soon as possible.
The loading process is opposite to the unloading process.

NO

Model

(Nm3/h)

Inlet pressure

(Mpa)

Outlet pressure

(Mpa)

Moter POWER

(KW)

Dimensions

(mm)

1

ZW-0.6/16-24

550

1.6

2.4

11

1000×580×870

2

ZW-0.8/16-24

750

1.6

2.4

15

1000×580×870

3

ZW-1.0/16-24

920

1.6

2.4

18.5

1000×580×870

4

ZW-1.5/16-24

1380

1.6

2.4

30

1000×580×870

5

ZW-2.0/16-24

1500

1.6

2.4

37

1000×580×870

6

ZW-2.5/16-24

1880

1.6

2.4

45

1000×580×870

7

ZW-3.0/16-24

2250

1.6

2.4

55

1000×580×870

8

ZW-0.8/10-16

450

1.0

1.6

11

1100×740×960

9

ZW-1.1/10-16

600

1.0

1.6

15

1100×740×960

10

ZW-1.35/10-16

750

1.0

1.6

18.5

1100×740×960

11

ZW-1.6/10-16

950

1.0

1.6

22

1400×900×1180

12

ZW-2.0/10-16

1200

1.0

1.6

30

1400×900×1180

13

ZW-2.5/10-16

1500

1.0

1.6

37

1400×900×1180

14

ZW-3.0/10-16

1800

1.0

1.6

45

1400×900×1180

15

ZW-0.6/16-24

550

1.6

2.4

11

1500×800×1100

16

ZW-0.8/16-24

750

1.6

2.4

15

1500×800×1100

17

ZW-1.0/16-24

920

1.6

2.4

18.5

1500×800×1100

18

ZW-1.5/16-24

1380

1.6

2.4

30

1600×900×1200

19

ZW-2.0/16-24

1500

1.6

2.4

37

1600×900×1200

20

ZW-2.5/16-24

1880

1.6

2.4

45

1600×900×1200

21

ZW-3.0/16-24

2580

1.6

2.4

55

1600×900×1200

22

ZW-3.5/16-24

3000

1.6

2.4

55

1600×900×1200

23

ZW-4.0/16-24

3500

1.6

2.4

75

1600×900×1200

24

ZW-0.2/10-25

100

1

2.5

5.5

1000×580×870

25

ZW-0.4/10-25

220

1

2.5

11

1000×580×870

26

ZW-0.6/10-25

330

1

2.5

15

1000×580×870

27

ZW-0.2/25-40

260

2.5

4

7.5

1000×580×870

28

ZW-0.4/25-40

510

2.5

4

15

1000×580×870

29

ZW-0.5/25-40

660

2.5

4

18.5

1000×580×870

30

ZW-0.3/20-30

300

2

3

7.5

1000×580×870

31

ZW-0.4/20-30

420

2

3

11

1000×580×870

32

ZW-0.5/20-30

540

2

3

15

1000×580×870

33

ZW-0.6/20-30

630

2

3

15

1000×580×870

34

ZW-1.6/20-30

1710

2

3

37

1400×900×1180


Product detail pictures:

OEM Hydrogen Compressor Model Manufacturers –  High Stable Belt Driven Ammonia unloading compressor – Huayan detail pictures


Related Product Guide:

We know that we only thrive if we can guarantee our combined price tag competiveness and top quality advantageous at the same time for OEM Hydrogen Compressor Model Manufacturers – High Stable Belt Driven Ammonia unloading compressor – Huayan , The product will supply to all over the world, such as: United States, Florence, Belize, Look forward to the future, we'll focus more on the brand building and promotion . And in the process of our brand global strategic layout we welcome more and more partners join us, work together with us based on mutual benefit. Let's develop market by fully utilizing our in depth advantages and strive for building.
  • Goods just received, we are very satisfied, a very good supplier, hope to make persistent efforts to do better.
    5 Stars By Maxine from Malta - 2018.06.18 19:26
    It is a very good, very rare business partners, looking forward to the next more perfect cooperation!
    5 Stars By Nicci Hackner from America - 2018.02.12 14:52
    Write your message here and send it to us